System (see, System tests, Memory tests – Dell PowerVault 725N (Rackmount NAS Appliance) User Manual

Page 6: Table 2, Lists the function keys, Types of system diagnostics program tests

Advertising
background image

 

 

Table 2-3. System Diagnostics Program

Function Keys  

 

Types of System Diagnostics Program Tests

 

System Tests

 

System tests help identify problems with system-board components such as processors, controllers, buses, and so on.

 

Select System from the system diagnostics program main menu to access the following tests:

l

 

Processor Tests – Tests processor functionality. The system diagnostics program provides four processor tests:

¡

 

Basic Functionality Test – Verifies that the processor operates correctly and efficiently in all addressing modes. The test is performed in 16-bit

real mode.

¡

 

Processor Speed Test – Determines and displays the processor clock speed. The screen displays the expected processor speed and the actual

processor clock speed. processor speed is determined by measuring the number of processor clock cycles that occur in a known time period.

¡

 

CPU Protected Mode Test – Verifies the protected-mode instructions used by the operating system for switching to protected mode.

¡

 

Coprocessor Test – Checks the functionality of the math coprocessor. This test loads and stores the control and status word, checks data

transfer between the processor and the math coprocessor, and tests exception checking while the data transfer is in progress.

l

 

DMA Controller Test – Performs a series of read and write tests on the memory address registers and page registers of the DMA controllers.

l

 

Interrupt Controller Test – Performs a series of read and write tests on interrupt mask registers and checks for stray interrupts after masking off all

interrupts.

l

 

Timer Test – Checks the accuracy of the timer count by calibrating it against the periodic interrupt of the Real Time Clock (RTC).

l

 

Real Time Clock Test – Checks the regularity of the real time clock interrupt by calibrating it against the timer 0 interrupt.

l

 

CMOS Validity Test – Checks the validity of the data in CMOS RAM and makes sure that the CMOS RAM checksum is correct. This test also ensures that

the battery is in good condition.

l

 

Speaker Test – Performs test on system speaker and allows you to adjust the volume.

l

 

PCI System Test – Scans the PCI bus for all PCI devices and checks their configurations.

l

 

SMBus Test – Checks that the System Management Bus (SMBus) works properly. This test consists of the SMBus general test and the SMB access test.

l

 

Hardware Monitor Tests – Reads the values for temperature, fan speed, and voltage to verify that they are within a specified range using the

following tests:

¡

 

Temperature and Fan Speed Test

¡

 

Voltage Test

 

Memory Tests

 

Memory tests, which report the size of system memory, write to all areas of installed DDR system memory up to 3 GB. The system diagnostics program isolates
faulty memory modules and displays a message that identifies the location of the faulty memory.

 

Select Memory from the system diagnostics program main menu to access the following tests:

For most of the options, any changes you make are recorded but do not take effect until you reboot the system. For a few options
(as noted in the help area at the bottom of the screen), the changes take effect immediately.

Key

Function

 

<F2>

 

Edit batch parameters.

 

<F3>

 

Load batch parameters.

 

<F4>

 

Save batch parameters.

 

<F5>

 

Select/deselect current test.

 

<F6>

 

Select/deselect All Tests in Menu.

 

<F7>

 

Select/deselect All Tests.

 

<F8>

 

Select/deselect All Quick Tests.

 

<F9>

 

List function keys.

 

<F10>  Run the selected test.