Checking the expander firmware version – Dell PowerEdge C8000 User Manual

Page 58

Advertising
background image

58

Troubleshooting

3 Ensure that the node power distribution board is installed properly in the

sled.

4 Reinstall the sled into the enclosure. See "Installing a Sled" on page 31.

If the problem persists, see "Getting Help" on page 77.

Checking the Expander Firmware Version

NOTE:

Download and install the latest expander firmware version from

support.dell.com. Follow the instructions included in the file download to install the

update on your system.

1 Run the command line interface.
2 Check the inband SAS address.

Enter the following command line to get the inband SAS address:

cmd>xflash -i get avail
where
i - selects the interface is the inband SAS address
get - queries data from the targeted expander chip
avail - lists expanders available to the selected interface

3 Check the expander chip firmware version.

Enter the following command line to view the expander chip firmware

version:

cmd>xflash -i SASADDR get ver 0,
where
i - selects the interface is the inband SAS address
SASADDR - is the inband SAS address of the specified expander chip
get - queries data from the targeted expander chip
ver [REGION] - display the version of firmware in a flash region. If

specified, [REGION] refers to any expander flash region (0 to 9). If

not specified, displays the version of the active firmware region.
For example, the command line should have the following format:
cmd>xflash -i

500650b0000472bf get ver 0