Expander firmware update guidelines, Updating the expander firmware – Dell PowerEdge C8000 User Manual

Page 65

Advertising
background image

Using the Expander Flash Utility

65

Expander Firmware Update Guidelines

The following are the recommended guidelines for updating the expander

firmware.

• Firmware update must be downloaded in each flash region starting with

flash region 0.

• Do not erase the expander firmware flash image when the firmware update

is in progress, this clears the SAS expander's SAS address.

• If you encounter a firmware update failure with your storage sled, you can

use the SAS expander's smart debug connector to recover the failed

firmware update. For the location of the connector, see "SAS Expander

Board Connectors" on page 74.

WARNING:

It is strongly recommended that you always update firmware on both

expander chips and to reset the SAS expander after the update operation has
completed.

Updating the Expander Firmware

NOTE:

Before performing the firmware update, make sure to download the latest

firmware version and save it on your local system. During the process of an

expander firmware update, the C8000XD sled must not be removed from the C8000

server enclosure.

CAUTION:

Do not erase the expander firmware flash image when the firmware

update is in progress, this clears the inband SAS address.

1 Connect the storage sled and the compute sled’s HBA or RAID card. See

"Cabling Configurations" on page 62 for the supported cabling

configurations.

2 Download the latest expander firmware from support.dell.com. Browse to

the location where you downloaded the firmware package and extract the

package.

3 Check the current version of the expander firmware. See "Checking the

Expander Firmware Version" on page 58.

4 Identify the SAS addresses of the SAS expander by entering the command:

cmd>xflash –i get avail

Advertising