Dell PowerVault DP500 User Manual

Page 10

Advertising
background image

Invalid NVRAM configuration, Resource Re-

allocated

System detected and corrected a resource
conflict.

No action is required.

Keyboard Controller failure

Faulty keyboard controller; faulty system board

See

Getting Help

.

Manufacturing mode detected

System is in manufacturing mode.

Reboot to take the system out of manufacturing mode.

MEMBIST failure - The following DIMM/rank

has been disabled by BIOS: DIMM x Rank y

Faulty memory module(s).

See

Troubleshooting System Memory

.

Memory address line failure at address,

read value expecting value

Faulty or improperly installed memory modules.

See

Troubleshooting System Memory

.

Memory double word logic failure at

address, read value expecting value

Memory odd/even logic failure at address,

read value expecting value

Memory write/read failure at address, read

value expecting value

Memory tests terminated by keystroke.

POST memory test terminated by pressing the
spacebar.

Information only.

No boot device available

Faulty or missing optical/diskette drive
subsystem, hard drive, or hard-drive subsystem,
or no boot disk in drive A.

Use a bootable diskette, CD, or hard drive. If the problem
persists, see

Troubleshooting a Diskette Drive

,

Troubleshooting an Optical Drive

, and

Troubleshooting a

Hard Drive

. See

Using the System Setup Program

for

information on setting the order of boot devices.

No boot sector on hard drive

Incorrect configuration settings in System Setup
program, or no operating system on hard drive.

Check the hard-drive configuration settings in the System
Setup program. See

Using the System Setup Program

. If

necessary, install the operating system on your hard
drive. See your operating system documentation.

No timer tick interrupt

Faulty system board.

See "

Getting Help

."

Northbound merge error - The following

DIMM has been disabled by BIOS: DIMM x

The specified DIMM was unable to establish a
successful data link with the memory controller.

See

Troubleshooting System Memory

.

Not a boot diskette

No operating system on diskette.

Use a bootable diskette.

PCIe Degraded Link Width Error: Embedded

Bus#nn/Dev#nn/Funcn

Expected Link Width is n

Actual Link Width is n

Faulty or improperly installed PCIe card in the
specified slot.

Reseat the PCIe card in the specified slot number. See

Expansion Cards

. If the problem persists, see

Getting

Help

.

PCIe Degraded Link Width Error: Slot n

Expected Link Width is n

Actual Link Width is n

Faulty or improperly installed PCIe card in the
specified slot.

Reseat the PCIe card in the specified slot number. See

Expansion Cards

. If the problem persists, see

Getting

Help

.

PCIe Training Error: Embedded

Bus#nn/Dev#nn/Funcn

PCIe Training Error: Slot n

Faulty or improperly installed PCIe card in the
specified slot.

Reseat the PCIe card in the specified slot number. See

Expansion Cards

. If the problem persists, see

Getting

Help

.

PCI BIOS failed to install

PCI device BIOS (Option ROM) checksum failure
is detected during shadowing.

Loose cables to expansion card(s); faulty or
improperly installed expansion card(s).

Reseat the expansion card(s). Ensure that all appropriate
cables are securely connected to the expansion card(s).
If the problem persists, see

Troubleshooting Expansion

Cards

.

Plug & Play Configuration Error

Error encountered in initializing PCI device;
faulty system board.

Install the NVRAM_CLR jumper and reboot the system.
See

Figure 6

-1

for jumper location. If the problem

persists, see

Troubleshooting Expansion Cards

.

Read fault

Requested sector not found

The operating system cannot read from the
diskette or hard drive, the system could not find
a particular sector on the disk, or the requested
sector is defective.

Replace the diskette. Ensure that the diskette and hard
drive cables are properly connected. See

Troubleshooting

a USB Device

, or

Troubleshooting a Hard Drive

for the

appropriate drive(s) installed in your system.

Remote configuration update attempt failed

System unable to process Remote Configuration
request

Retry Remote Configuration.

ROM bad checksum = address

Expansion card improperly installed or faulty.

Reseat the expansion card(s). Ensure that all appropriate
cables are securely connected to the expansion card(s).
If the problem persists, see

Troubleshooting Expansion

Cards

.

Sector not found

Seek error

Seek operation failed

Faulty diskette or hard drive.

See

Troubleshooting a Diskette Drive

,

Troubleshooting a

USB Device

, or

Troubleshooting a Hard Drive

for the

appropriate drive(s) installed in your system.

Shutdown failure

Shutdown test failure.

See

Troubleshooting System Memory

.

The amount of system memory has changed

Memory has been added or removed or a
memory module may be faulty.

If memory has been added or removed, this message is
informative and can be ignored. If memory has not been
added or removed, check the SEL to determine if single-
bit or multi-bit errors were detected and replace the
faulty memory module. See

Troubleshooting System

Memory

.

Time-of-day clock stopped

Faulty battery or faulty chip.

See

Troubleshooting the System Battery

.

The following DIMM pair is not compatible

The specified DIMM(s) are incompatible with the

Ensure that only Dell-qualified memory is used. Dell

Advertising