Solving Problems Described by LCD Status Messages

The code and text on the LCD can often specify a very precise fault condition that is easily corrected. For example, if the code E1418  CPU_1_Presence
appears, you know that a microprocessor is not installed in socket 1.

In contrast, you might be able to determine the problem if multiple related errors occur. For example, if you receive a series of messages indicating multiple
voltage faults, you might determine that the problem is a failing power supply.

 

Removing LCD Status Messages

For faults associated with sensors, such as temperature, voltage, fans, and so on, the LCD message is automatically removed when that sensor returns to a
normal state. For example, if temperature for a component goes out of range, the LCD displays the fault; when the temperature returns to the acceptable
range, the message is removed from the LCD. For other faults, you must take action to remove the message from the display:

l

 

Clear the SEL — You can perform this task remotely, but you will lose the event history for the system.

l

 

Power cycle — Turn off the system and disconnect it from the electrical outlet; wait approximately ten seconds, reconnect the power cable, and restart

the system.

Any of these actions will remove fault messages, and return the status indicators and LCD colors to the normal state. Messages will reappear under the
following conditions:

l

 The sensor returns to a normal state but fails again, resulting in a new SEL entry.

l

 

The system is reset and new error events are detected.

l

 

A failure is recorded from another source that maps to the same display entry.

E201C SMI Init

System management interrupt (SMI) initialization failure.

See

Getting Help

.

E201D Shutdown Test

BIOS shutdown test failure.

See

Getting Help

.

E201E POST Mem Test

BIOS POST memory test failure.

See

Troubleshooting System Memory

. If problem persists, see

Getting

Help

.

E201F DRAC Config

Dell remote access controller (DRAC) configuration failure.

Check screen for specific error messages.

Ensure that DRAC cables and connectors are properly seated. If
problem persists, see your DRAC documentation.

E2020 CPU Config

CPU configuration failure.

Check screen for specific error messages.

E2021 Memory

Population

Incorrect memory configuration. Memory population order
incorrect.

Check screen for specific error messages. See

Troubleshooting System

Memory

.

E2022 POST Fail

General failure after video.

Check screen for specific error messages.

E2110 MBE Crd #

DIMM ## & ##

One of the DIMMs in the set implicated by "## & ##" has
had a memory multi-bit error (MBE). If no memory card is
present, the "Crd #" string is left out of the message.

See

Troubleshooting System Memory

.

E2111 SBE Log

Disable Crd #

DIMM ##

The system BIOS has disabled memory single-bit error (SBE)
logging, and will not resume logging further SBEs until the
system is rebooted. "##" represents the DIMM implicated
by the BIOS. If no memory riser card is present, the "Crd #"
string is left out of the message.

See

Troubleshooting System Memory

.

E2112 Mem Spare Crd

# DIMM ##

The system BIOS has spared the memory because it has
determined that the memory had too many errors. "## &
##" represents the DIMM pair implicated by the BIOS. If no
memory card is present, the "Crd #" string is left out of the
message.

See

Troubleshooting System Memory

.

E2113 Mem Mirror

Crd # DIMM ##

& ##

The system BIOS has disabled memory mirroring because it
has determined that one half of the mirror has had too
many errors. "## & ##" represents the DIMM pair
implicated by the BIOS. If no memory card is present, the
"Crd #" string is left out of the message.

See

Troubleshooting System Memory

.

E2118 Fatal NB Mem

CRC

One of the connections in the Fully Buffered DIMM (FBD)
memory subsystem link on the Northbound side has failed.

See

Troubleshooting System Memory

.

E2119 Fatal SB Mem

CRC

One of the connections in the FBD memory subsystem link
on the Southbound side has failed.

See

Troubleshooting System Memory

.

I1910 Intrusion

System cover has been removed.

Information only.

I1911 >3 ERRs Chk

Log

LCD overflow message.

A maximum of three error messages can display sequentially
on the LCD. The fourth message displays as the standard
overflow message.

Check the SEL for details on the events.

I1912 SEL Full

System Event Log is full of events, and is unable to log any
more events.

Clear the log by deleting event entries.

W1228 ROMB Batt <

24hr

Warns predictively that the RAID battery has less than 24
hours of charge left.

Replace RAID battery. See

RAID Battery

.

 

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

Glossary

.