About Your System

23

E1421

CPU Init

The system BIOS has reported a
processor initialization error.

See "Getting Help" on page 147.

E1422

CPU Machine Chk

The system BIOS has reported a
machine check error.

See "Getting Help" on page 147.

E1610

PS # Missing

No power is available from the
specified power supply; specified
power supply is improperly
installed or faulty.

See "Troubleshooting Power
Supplies" on page 122.

E1614

PS # Status

No power is available from the
specified power supply; specified
power supply is improperly
installed or faulty.

See "Troubleshooting Power
Supplies" on page 122.

E1618

PS # Predictive

Power supply voltage is out of
acceptable range; specified power
supply is improperly installed or
faulty.

See "Troubleshooting Power
Supplies" on page 122.

E161C

PS # Input Lost

Power source for specified power
supply is unavailable, or out of
acceptable range.

Check the AC power source for
the specified power supply. If the
problem persists, see
"Troubleshooting Power Supplies"
on page 122.

E1620

PS # Input Range

Power source for specified power
supply is unavailable, or out of
acceptable range.

Check the AC power source for
the specified power supply. If the
problem persists, see
"Troubleshooting Power Supplies"
on page 122.

E1624

PS Redundancy

The power supply subsystem is no
longer redundant. If the last
supply fails, the system will go
down.

See "Troubleshooting Power
Supplies" on page 122.

E1625

PS AC Current

Power source is out of acceptable
range.

Check the AC power source.

E1710

I/O Channel Chk

The system BIOS has reported an
I/O channel check.

See "Getting Help" on page 147.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

Advertising