Installing the cooling shroud, Out of the system. see figure 3-15 – Dell PowerEdge 2970 User Manual

Page 75

Advertising
background image

Installing System Components

75

Figure 3-15.

Removing and Installing the Cooling Shroud

Installing the Cooling Shroud

1 Align the hinges on the shroud with the pivots located on each end of the fan bracket. See Figure 3-15.
2 Lower the shroud straight down into the system until the hinges snap into place on the pivots.
3 Rotate the shroud down over the processor(s) and memory modules.
4 Route the optical drive cable through the cable tabs on top of the cooling shroud.
5 Reinstall the left riser board. See "Installing the Left Riser Board" on page 103.
6 Reinstall the expansion cards into the left riser board. "Installing an Expansion Card" on page 72.
7 Close the system. See "Closing the System" on page 56.
8 Reconnect the system to the electrical outlet and turn on the system and attached peripherals.