Troubleshooting Your System

Troubleshooting a Fan

Problem

System-status indicator is amber.

Systems management software issues a fan-related error message.

Action

CAUTION:

Only trained service technicians are authorized to remove the system

cover and access any of the components inside the system. Before performing any
procedure, see your Product Information Guide for complete information about
safety precautions, working inside the computer and protecting against
electrostatic discharge.

1 Run the appropriate diagnostic test. See "Using Dell PowerEdge

Diagnostics" on page 117.

2 Open the system. See "Opening the System" on page 54.
3 Ensure that the faulty fan's power cable is firmly attached to the fan power

connector. See "Fan Assembly" on page 68.

NOTE:

Wait 30 seconds for the system to recognize the fan and determine

whether it is working properly.

4 If the problem is not resolved, install a new fan. See "Fan Assembly" on

page 68.

If the replacement fan is working properly, close the system. See "Closing
the System" on page 55.

If the replacement fan does not operate, see "Getting Help" on page 127.

Troubleshooting System Memory

Problem

Faulty memory module.

Faulty system board.

Diagnostic indicator code indicates a problem with system memory.