Dell PowerEdge R200 User Manual

Page 21

Advertising
background image

About Your System

21

Decreasing

available memory

One or more memory
modules might be
improperly seated or faulty.

Reinstall the memory
modules and, if necessary,
replace them. See "System
Memory" on page 81.

See "Troubleshooting
System Memory" on
page 108.

Diskette read

failure

Faulty or improperly
inserted diskette.

Replace the diskette.

Diskette subsystem

reset failed

Faulty diskette drive or
optical drive controller.

Ensure that the diskette
drive and optical drive
cables are properly
connected. See
"Troubleshooting a USB
Device" on page 102 and
"Troubleshooting an
Optical Drive" on page 110.
If the problem persists, see
"Getting Help" on
page 127.

Drive not ready

Diskette missing or
improperly inserted in
diskette drive.

Reinsert or replace the
diskette.

Error: Incorrect

memory

configuration.

Ensure memory in

slots DIMM1_A and

DIMM1_B, DIMM2_A

and DIMM2_B match

identically in

size, speed and

rank.

The installed memory
modules are not matched
pairs.

See "Memory Module
Installation Guidelines" on
page 81.

Table 1-4.

System Messages (continued)

Message

Causes

Corrective Actions

book.book Page 21 Thursday, August 30, 2007 3:30 PM