About Your System

Plug & Play

Configuration Error

Error encountered in
initializing PCI device;
faulty system board.

Install the NVRAM_CLR
jumper and reboot the
system. See Figure 6-1 for
jumper location. Check for
a BIOS update. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 113. If the problem
persists, see "Getting Help"
on page 127.

Read fault

Requested sector

not found

The operating system
cannot read from the
diskette or hard drive, the
system could not find a
particular sector on the
disk, or the requested sector
is defective.

Replace the diskette.
Ensure that the diskette
and hard-drive cables are
properly connected. See
"Troubleshooting a USB
Device" on page 102
or
"Troubleshooting a Hard
Drive" on page 111 for the
appropriate drive(s)
installed in your system.

Remote

Configuration

update attempt

failed

System could not
implement Remote
Configuration request.

Retry Remote
Configuration.

SATA port 0/1/2

hard disk drive

configuration error

Faulty drive. Parameters
failure.

Ensure that the hard drive
cables are properly
connected. See
"Troubleshooting a Hard
Drive" on page 111.

SATA port 0/1/2

hard disk drive

failure

SATA port 0/1/2

hard disk drive

auto-sensing error

Faulty drive. INT13 call
failure from the drive.

Ensure that the hard drive
cables are properly
connected. See
"Troubleshooting a Hard
Drive" on page 111.

Table 1-4.