About Your System

23

Manufacturing mode

detected

System is incorrectly
configured.

Memory address line

failure at

address

,

read

value

expecting

value

Memory double word

logic failure at

address

, read

value

expecting

value

Memory odd/even

logic failure at

start address

to

end address

Memory write/read

failure at

address

,

read

value

expecting

value

Faulty or improperly
installed memory modules,
or faulty system board.

Ensure that all memory
modules are properly
installed. See
"Troubleshooting System
Memory" on page 108. If
the problem persists, see
"Getting Help" on
page 127.

Memory tests

terminated by

keystroke

The spacebar was pressed
during POST to terminate
the memory test.

Information only.

No boot device

available

The system cannot find the
diskette or hard drive.

If the diskette drive is your
boot device, ensure that a
bootable disk is in the drive.

If the hard drive is your
boot device, ensure that the
hard drive is installed,
properly seated, and
partitioned as a boot
device.

Enter the System Setup
program and verify the boot
sequence information. See
your

Hardware Owner’s

Manual for details.

Table 1-4.

System Messages (continued)

Message

Causes

Corrective Actions