About Your System

Table 1-6.

System Beep Codes

Code

Cause

Corrective Action

1-1-2

CPU register test failure

See "Troubleshooting the Microprocessor"
on page 114.

1-1-3

CMOS write/read failure;
faulty system board

Faulty system board. See "Getting Help"
on page 127.

1-1-4

BIOS error

Reflash the BIOS.

1-2-1

Programmable interval-timer
failure; faulty system board

Faulty system board. See "Getting Help"
on page 127.

1-2-2

DMA initialization failure

See "Troubleshooting System Memory" on
page 108.

1-2-3

DMA page register write/read
failure

1-3-1

Main-memory refresh
verification failure

1-3-2

No memory installed

1-3-3

Chip or data line failure in the
first 64 KB of main memory

1-3-4

Odd/even logic failure in the
first 64 KB of main memory

1-4-1

Address line failure in the first
64 KB of main memory

1-4-2

Parity failure in the first 64 KB
of main memory

1-4-3

Fail-safe timer test failure

1-4-4

Software NMI port test failure

2-1-1
through
2-4-4

Bit failure in the first 64 KB of
main memory