A b c d – Dell Dimension 4600 User Manual

Page 56

Advertising
background image

56

A d v a n c e d Tr o u b l e s h o o t i n g

www

.dell.com | support.dell.com

A possible USB failure has occurred.

Reinstall all USB devices, check
cable connections, and then restart
the computer.

No memory modules are detected.

• Reinstall all memory modules

(see page 95) and restart the
computer.

• To eliminate the possibility of a

faulty memory connector,
remove all memory modules
(see page 95), reinstall one
memory module (if the
computer supports a single
module), and then restart the
computer. If the computer starts
normally, move the memory
module to a different connector
and restart the computer.
Continue until you have
identified a faulty connector or
reinstalled all modules without
error.

Memory modules are detected, but a
memory configuration or
compatibility error exists.

• Ensure that there are no special

memory module/memory
connector placement
requirements (see page 95).

• Verify that the memory modules

that you are installing are
compatible with your computer
(see page 95).

• If the problem persists, contact

Dell (see page 113).

Light Pattern

Problem Description

Suggested Resolution

= y e l l o w

= g r e e n

= o f f

A B C D

A B C D

A B C D

J2936bk0.book Page 56 Tuesday, September 2, 2003 3:06 PM