Event log messages, Offload iscsi (ois) driver – Dell Broadcom NetXtreme Family of Adapters User Manual

Page 98

Advertising
background image

iSCSI Protocol: Broadcom NetXtreme II® Network Adapter User Guide

file:///C|/Users/Nalina_N_S/Documents/NetXtremeII/English/iscsi.htm[9/5/2014 3:45:06 PM]

Event Log Messages

Table 5

lists the offload iSCSI driver event log messages.

Offload iSCSI (OIS) Driver

Table 5: Offload iSCSI (OIS) Driver Event Log Messages

Message

Number Severity

Message

1

Error

Initiator failed to connect to the target. Target IP address and TCP Port number are given in dump

data.

2

Error

The initiator could not allocate resources for an iSCSI session.

3

Error

Maximum command sequence number is not serially greater than expected command sequence

number in login response. Dump data contains Expected Command Sequence number followed by

Maximum Command Sequence number.

4

Error

MaxBurstLength is not serially greater than FirstBurstLength. Dump data contains FirstBurstLength

followed by MaxBurstLength.

5

Error

Failed to setup initiator portal. Error status is given in the dump data.

6

Error

The initiator could not allocate resources for an iSCSI connection

7

Error

The initiator could not send an iSCSI PDU. Error status is given in the dump data.

8

Error

Target or discovery service did not respond in time for an iSCSI request sent by the initiator. iSCSI

Function code is given in the dump data. For details about iSCSI Function code please refer to iSCSI

User's Guide.

9

Error

Target did not respond in time for a SCSI request. The CDB is given in the dump data.

10

Error

Login request failed. The login response packet is given in the dump data.

11

Error

Target returned an invalid login response packet. The login response packet is given in the dump

data.

12

Error

Target provided invalid data for login redirect. Dump data contains the data returned by the target.

13

Error

Target offered an unknown AuthMethod. Dump data contains the data returned by the target.

14

Error

Target offered an unknown digest algorithm for CHAP. Dump data contains the data returned by the

target.

15

Error

CHAP challenge given by the target contains invalid characters. Dump data contains the challenge

given.

16

Error

An invalid key was received during CHAP negotiation. The key=value pair is given in the dump data.

17

Error

CHAP Response given by the target did not match the expected one. Dump data contains the CHAP

response.

18

Error

Header Digest is required by the initiator, but target did not offer it.

19

Error

Data Digest is required by the initiator, but target did not offer it.

20

Error

Connection to the target was lost. The initiator will attempt to retry the connection.

21

Error

Data Segment Length given in the header exceeds MaxRecvDataSegmentLength declared by the

target.

22

Error

Header digest error was detected for the given PDU. Dump data contains the header and digest.

23

Error

Target sent an invalid iSCSI PDU. Dump data contains the entire iSCSI header.

24

Error

Target sent an iSCSI PDU with an invalid opcode. Dump data contains the entire iSCSI header.

25

Error

Data digest error was detected. Dump data contains the calculated checksum followed by the given

checksum.

26

Error

Target trying to send more data than requested by the initiator.

27

Error

Initiator could not find a match for the initiator task tag in the received PDU. Dump data contains the

entire iSCSI header.

28

Error

Initiator received an invalid R2T packet. Dump data contains the entire iSCSI header.

29

Error

Target rejected an iSCSI PDU sent by the initiator. Dump data contains the rejected PDU.

30

Error

Initiator could not allocate a work item for processing a request.

31

Error

Initiator could not allocate resource for processing a request.

Advertising