Error Code

Message Information

AMP0302

Message

The system board <

name

> current is greater than the upper warning

threshold.

Details

System board <

name

> current is outside of the optimum range.

Action

1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see

Getting Help

.

AMP0303

Message

The system board <

name

> current is greater than the upper critical

threshold.

LCD Message

System board <

name

> current is outside of range.

Details

System board <

name

> current is outside of the optimum range.

Action

1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see

Getting Help

.

ASR0000

Message

The watchdog timer expired.

Details

The operating system or an application failed to communicate within
the time-out period.

Action

Check the operating system, application, hardware, and system event
log for exception events.

ASR0001

Message

The watchdog timer reset the system.

Details

The operating system or an application failed to communicate within
the time-out period. The system was reset.

Action

Check the operating system, application, hardware, and system event
log for exception events.

ASR0002

Message

The watchdog timer powered off the system.

Details

The operating system or an application failed to communicate within
the time-out period. The system was shut down.

Action

Check the operating system, application, hardware, and system event
log for exception events.