Error Code

Message Information

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1320

Message

A bus fatal error was detected on a component at bus
<

bus

>device<

device

>function <

func

>.

LCD Message

Bus fatal error on bus <

bus

> device <

device

> function <

func

>. Power

cycle system.

Details

System performance may be degraded, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1342

Message

A bus time-out was detected on a component at slot <

number

>.

Details

System performance may be degraded, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1348

Message

A PCI parity error was detected on a component at slot <

number

>.

LCD Message

PCI parity error on slot <

number

>. Re-seat PCI card.

Details

System performance may be degraded, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1360

Message

A bus fatal error was detected on a component at slot <

number

>.

LCD Message

Bus fatal error on slot <

number

>. Re-seat PCI card.

Details

System performance may be degraded, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PDR0001

Message

Fault detected on drive <

number

>.

LCD Message

Fault detected on drive <

number

>. Check drive.

Details

The controller detected a failure on the disk and has taken the disk
offline.

Action

Remove and re-seat the failed disk. If the issue persists, see

Getting

Help

.

PDR1016

Message

Drive <

number

> is removed from disk drive bay <

bay

>.

113