Error Code

Message Information

Action

Review the technical specifications for supported processor types.

CPU0010

Message

CPU <

number

> is throttled.

Details

The CPU is throttled due to thermal or power conditions.

Action

Review system logs for power or thermal exceptions.

CPU0023

Message

CPU <

number

> is absent.

LCD Message

CPU <

number

> is absent. Check CPU.

Action

Verify processor installation. If present, re-seat the processor.

CPU0204

Message

CPU <

number

> <

name

> voltage is outside of range.

LCD Message

CPU <

number

> <

name

> voltage is outside of range. Re-seat CPU.

Details

Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.

Action

1. Turn off the system and remove input power for one minute.
2. Ensure the processor is seated correctly.
3. Reapply input power and turn on the system.
4. If the issue persists, see

Getting Help

.

CPU0700

Message

CPU <

number

> initialization error detected.

LCD Message

CPU <

number

> initialization error detected. Power cycle system.

Details

System BIOS was unable to initialize the processor.

Action

1. Turn off the system and remove input power for one minute.
2. Ensure the processor is seated correctly.
3. Reapply input power and turn on the system.
4. If the issue persists, see

Getting Help

.

CPU0701

Message

CPU <

number

> protocol error detected.

LCD Message

CPU <

number

> protocol error detected. Power cycle system.

Details

System event log and operating system logs may indicate that the
exception is external to the processor.

Action

1. Check system and operating system logs for exceptions. If no

exceptions are found, continue.