Enclosure alarms – Dell PowerVault MD1120 User Manual

Page 20

Advertising
background image

20

About Your System

Enclosure Alarms

An audible alarm is activated if any of the fault conditions listed in Table 1-6
occur. If a critical event occurs, the alarm sounds continuously. If a noncritical
event occurs, the alarm sounds every 10 seconds.

NOTE:

The audible alarm is disabled by default. To enable the alarm, you must

change the default setting in server administrator. For more information, see server
administrator storage management service documentation.

NOTE:

It is rare for both EMMs to fail simultaneously. However, if this occurs, the

enclosure cannot issue critical or noncritical event alarms for any enclosure
component.

Table 1-6.

Critical and Noncritical Events

Critical Events

Noncritical Events

Two or more fan blowers have failed or
a power supply/cooling fan module is
not installed.

One power supply has failed.

One or more temperature sensors are
in critical range.

One cooling fan has failed.

One or more temperature sensors are in
warning range.

One EMM has failed.