Table 81, Table 82 – Dell POWEREDGE M1000E User Manual

Page 424

Advertising
background image

384

Fabric OS Administrator’s Guide

53-1001763-02

Advanced Performance Monitoring overview

17

ISL monitors measure the traffic transmitted through an InterSwitch Link (ISL) to different
destination domains.

Top Talkers monitors measure the flows that are major consumers of bandwidth on a switch or
port.

The type of monitors supported depends on the switch model, as shown in

Table 81

.

NOTE

Advanced Performance Monitoring is not supported on VE_Ports and EX_Ports. If you issue
commands for any Advanced Performance Monitors on VE_Ports or EX_Ports you will receive error
messages.

Virtual Fabrics considerations for Advanced Performance Monitoring

In a fabric with Virtual Fabrics enabled, the number of logical switches that can be configured with
monitors is restricted.

Table 82

lists the platforms that support logical switches and, for each

platform, the maximum number of logical switches that can support performance monitors.

Each logical switch can have its own set of performance monitors. The installation of monitors is
restricted to the ports that are present in the respective logical switch.

Top Talker and end-to-end monitors are supported on the default logical switch, the base
switch, and user-defined logical switches.

Frame monitors are not supported on logical ISLs (LISLs) in user-defined logical switches.

ISL monitors are not supported on any of the platforms listed in

Table 82

.

If you move a port from one logical switch to another, the behavior of monitors installed on that port
is as follows:

Frame monitor: Any frame monitors on the port are deleted. To keep the frame monitor, you
must manually install it on the port after the move.

TABLE 81

Types of monitors supported on Brocade switch models

Platform

Monitors:

EE

Frame ISL

Top Talker

Brocade 300, 5300, 7800

Yes Yes

No

Yes

Brocade 5410, 5424, 5450, and 5480

Yes Yes

No

No

Brocade 4100, 4900, 5000, 7500, 7500E, 7600, and 48000

Yes Yes

Yes Yes

Brocade 5100, 8000

1

, VA-40FC, Brocade Encryption Switch,

Brocade DCX, Brocade DCX-4S

1.

For the Brocade 8000, performance monitoring is supported only on the FC ports and not on the CEE ports.

Yes Yes

No

Yes

TABLE 82

Number of logical switches that support performance monitors

Platform

Maximum number of logical switches supported

Maximum number of logical switches on which
monitors are supported

Brocade DCX

8

4

Brocade DCX-4S

8

4

Brocade 5100
Brocade VA-40FC

3

3

Brocade 5300

4

3

Advertising