386

Fabric OS Administrator’s Guide

53-1001763-02

End-to-end performance monitoring

17

The monitor count is qualified using either of the following conditions:

For frames received at the port with the end-to-end monitor installed, the frame SID is the
same as “SourceID” and the frame DID is the same as “DestID”. The RX_COUNT updated
accordingly.

For frames transmitted from the port with the end-to-end monitor installed, the frame DID is
the same as “SourceID” and the frame SID is the same as “DestID”. The TX_COUNT updated
accordingly.

Virtual Fabrics considerations: If Virtual Fabrics is enabled, the Brocade DCX, DCX-4S, and 5300
models allow up to 256 end-to-end monitors on one logical switch. The Brocade 5100 and VA-40FC
allow up to 337 end-to-end monitors on one logical switch.

Adding end-to-end monitors

1. Connect to the switch and log in as admin.

2. Enter the following command:

perfaddeemonitor [slotnumber/]portnumber sourceID destID

Figure 58

shows two devices:

Host A is connected to domain 5 (0x05), switch area ID 18 (0x12), AL_PA 0x00 on Switch X.

Dev B is a storage device connected to domain 17 (0x11), switch area ID 30 (0x1e), AL_PA 0xef
on Switch Y.

FIGURE 58

Setting end-to-end monitors on a port

End-to-end performance monitoring looks at traffic on SID/DID pairs in any direction. That is, even
if the SID is for a remote device, the traffic is monitored in both directions (the Tx/Rx counters are
reversed).

Example of monitoring the traffic from Host A to Dev B

Add Monitor 0 to slot 2, port 2 on Switch X, specifying 0x051200 as the SID and 0x111eef as the
DID, as shown in the following example:

switch:admin> perfaddeemonitor 2/2, "0x051200" "0x111eef"
End-to-End monitor number 0 added.

Monitor 0 counts the frames that have an SID of 0x051200 and a DID of 0x111eef. For monitor 0,
RX_COUNT is the number of words from Host A to Dev B, and TX_COUNT is the number of words
from Dev B to Host A.

Example of monitoring the traffic from Dev B to Host A

Add Monitor 1 to slot 2, port 14 on Switch Y, specifying 0x111eef as the SID and 0x051200 as the
DID, as shown in the following example.

switch:admin> perfaddeemonitor 2/14, "0x111eef" "0x051200"
End-to-End monitor number 1 added.

. . .

0x051200

0x111eef

Host

A

DID

SID

. . .

Dev

B

Switch X

Switch Y

Monitor 0
domain 0x05, switch area ID 0x12
AL_PA 0x00

Monitor 1
domain 0x11, switch area ID 0x1e
AL_PA 0xef