Changing bottleneck alert parameters, Changing bottleneck alert, Parameters – Dell POWEREDGE M1000E User Manual

Page 460

Advertising
background image

420

Fabric OS Administrator’s Guide

53-1001763-02

Displaying bottleneck detection configuration details

18

1. Connect to the switch to which the target port belongs and log in as admin.

2. Enter the bottleneckmon

--

exclude command to exclude the port from bottleneck detection.

To later include the port, enter the bottleneckmon

--

include command.

Example

switch:admin> bottleneckmon --exclude 4

Displaying bottleneck detection configuration details

Using the following procedure, you can display details of the bottleneck detection configuration,
including the following:

Whether the feature is enabled

Switch-wide alerting parameters

Port-specific alerting parameters

Excluded ports

1. Connect to the switch and log in as admin.

2. Enter the bottleneckmon

--

status command to display the details of bottleneck detection

configuration for the switch.

Example

switch:admin> bottleneckmon --status
Bottleneck detection - Enabled
==============================

Switch-wide alerting parameters:
============================
Alerts - Yes
Latency threshold for alert - 0.100
Congestion threshold for alert - 0.800
Averaging time for alert - 300 seconds
Quiet time for alert - 300 seconds

Excluded ports:
===============
Port
====
12
13
14

Changing bottleneck alert parameters

When you enable bottleneck detection, you can configure alert parameters that apply to every port
on the switch. After you enable bottleneck detection, you can change the alert parameters on all
eligible ports on the switch or on individual ports. You can also change the alert parameters on
ports that have been excluded from bottleneck detection.

Advertising