Figure 70, Edge – Dell POWEREDGE M1000E User Manual

Page 500

Advertising
background image

460

Fabric OS Administrator’s Guide

53-1001763-02

Fibre Channel routing concepts

21

NOTE

Backbone fabrics that share connections to the same edge fabrics must have unique
backbone fabric IDs.

MetaSAN
A metaSAN is the collection of all SANs interconnected with Fibre Channel routers.

A simple metaSAN can be constructed using an FC router to connect two or more separate
fabrics. Additional FC routers can be used to increase the available bandwidth between fabrics
and to provide redundancy.

Figure 70

shows a metaSAN consisting of a host in Edge SAN 1 connected to storage in Edge

SAN 2 through a backbone fabric connecting two FC routers.

FIGURE 70

Edge SANs connected through a backbone fabric

Phantom domains
A phantom domain is a domain emulated by the Fibre Channel router. The FC router can
emulate two types of phantom domains: front phantom domains and translate phantom
domains. For detailed information about phantom domains, see

“Phantom domains”

on

page 462.

= LSAN

Edge SAN 2

Edge SAN 1

Backbone

fabric

FC router

FC router

E_Port

E_Port

IFL

IFL

EX_Port

EX_Port

ISL

Advertising