19

System Messages

System messages appear on the screen to notify you of a possible problem

with the system.

NOTE:

If you receive a system message not listed in the table, check the

documentation for the application that is running when the message appears or the

operating system's documentation for an explanation of the message and

recommended action.

Message

Causes

Corrective Actions

BIOS

MANUFACTURING

MODE detected.

MANUFACTURING

MODE will be

cleared before

the next boot.

System reboot

required for

normal

operation.

System is in manufacturing

mode.

Reboot to take the system

out of manufacturing mode.

Caution!

NVRAM_CLR jumper

is installed on

system board.

Please run

SETUP.

NVRAM_CLR jumper is

installed in the clear setting.

CMOS has been cleared.

Move the NVRAM_CLR

jumper to the default

position (pins 3 and 5). See

Figure 8-1 for jumper

location. Restart the system

and re-enter the BIOS

settings. See "Using the

System Setup Program and

Boot Manager" on page 25.

Invalid

configuration

information -

please run SETUP

program.

An invalid system

configuration caused a

system halt.

Run the System Setup

program and review the

current settings. See "Using

the System Setup Program

and Boot Manager" on

page 25.

Keyboard

controller

failure.

Faulty keyboard controller;

faulty system board.

See "Getting Help" on

page 119.