Dell Compellent Series 30 User Manual

Page 192

Advertising
background image

184

Storage Center 5.5 System Manager User Guide

Controllers

Figure 152. Add iSCSI Remote Compellent Connections window

Note

If the Remote Compellent system is using iSCSI Virtual Ports, add the IP Addresses
of the Control Ports. If the Remote Compellent system is not using iSCSI Virtual
Ports, add the IP Addresses of the IO Cards (physical ports).

4 Add the IP Address of the Control Port of System 2. The IP Address appears in the

iSCSI folder containing the Control Port.

5 When you have entered the IP address and CHAP name of System 2, click Continue.

An additional Add iSCSI Remote Compellent Connections window appears.

6 On the second window, enter the CHAP Name of the Compellent port on System 2.

7 Enter a Target Secret for the remote connection. The Target Secret must be at least 12

alphanumeric characters in length. It is the primary secret used in the connection
initiation process.

8 Enable or disable Bi-directional Authentication.

Note

The Remote Compellent CHAP Initiator secret on the remote Storage Center must
match the Target Secret on the local Storage Center.

9 Select Continue.

10 Select a link speed.

11 Click Continue. The CHAP verification window appears.

12 Click Add Now. In System 1, the Control Port IP address and system name of System

2 now appear in the Remote Compellent Connections window off all the iSCSI cards.

Advertising