Qlogic 23xx or 24xx (fc), For windows qlogic 40xx (iscsi) settings, refer to, Qlogic 40xx (iscsi) settings on – Dell Compellent Series 30 User Manual

Page 431

Advertising
background image

423

Settings by Server Operating System

->System

->CurrentControlSet

->Control

->Class

->{4D36E97B-E325-11CE-BFC1-08002BE10318}

-><Instance Number>

(which is the storage controller instance of the MS iSCSI Initiator)

->Parameters->

LinkDownTime

=120

Qlogic 23xx or 24xx (FC) Registry Key Settings

1 Set the following Windows registry key to 255:

HKEY_LOCAL_MACHINE\SYSTE

M\CurrentControlSet\Services\ql2300\Paramete

rs\Device\MaximumSGList

2 Set the following Windows registry key to 254:

HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\ql2300\Paramet

ers\Device\NumberOfRequests

3 For STORport drivers, set the following Window registry to qd=254

HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\ql2300\Paramet

ers\Device\DriverParameter

4 Reboot the server.

Qlogic 40XX (iSCSI) Settings

Set Execution Throttle

Use Qlogic SANsurfer for iSCSI to set the execution throttle for the installed ports to 250.
Be aware that the card must be reset, which can be performed without rebooting the server
through the SANsurfer interface.

Enable Address Resolution Protocol (ARP) Redirection on iSCSI HBA

1 From the QLogic SANsurfer iSCSI HBA Manager, select the Port Options tab and

then select the Firmware tab.

2 Select an HBA and enable ARP redirect by checking the box in the ARP Redirect

column. This setting is circled in red below.