Dell POWEREDGE 840 User Manual

Page 21

Advertising
background image

About Your System

21

Keyboard data line

failure

Keyboard failure

Keyboard stuck key

failure

Loose or improperly connected
keyboard cable; faulty keyboard;
faulty keyboard controller.

Ensure that the keyboard is properly
connected. If the problem persists,
replace the keyboard. If the problem
persists, see "Getting Help" on
page 121.

Keyboard fuse has failed.

Keyboard fuse has failed.

Replace the keyboard.

Manufacturing mode

detected

System is incorrectly configured.

Install the NVRAM_CLR jumper and
reboot the system. See "System Board
Jumpers" on page 115 for jumper
location.

Memory address line

failure at

address

, read

value

expecting

value

Memory double word logic

failure at

address

, read

value

expecting

value

Memory odd/even logic

failure at

address

, read

value

expecting

value

Memory write/read failure

at

address

, read

value

expecting

value

Faulty or improperly installed
memory modules, or faulty system
board.

Ensure that all memory modules are
properly installed. See
"Troubleshooting System Memory" on
page 100. If the problem persists, see
"Getting Help" on page 121.

Memory tests terminated

by keystroke

The spacebar was pressed during
POST to terminate the memory
test.

Information only.

More than one RAC

detected, system halted

Verify that the RAC is installed in the
proper PCI expansion slot (SLOT_5).
If a RAC is installed in any other slot,
remove it.

Table 1-6.

System Messages (continued)

Message

Causes

Corrective Actions