Plug) (see figure 3-12.), See figure 3-12). f – Dell POWEREDGE 840 User Manual

Page 62

Advertising
background image

62

Installing System Components

Figure 3-12.

Installing the SAS Backplane Board

5 Connect the power cable connector P3 to the power connector on the SAS backplane. See Figure 3-12.
6 Connect the baseboard management controller (BMC) inter-IC (I2C) cable to the SAS backplane. See

Figure 3-12.

7 Connect the other end of the BMC I2C cable to connector BP_I2C on the system board. See "System

Board Connectors" on page 118.

8 If not already installed, install the SAS controller card.

See "Installing an Expansion Card" on page 72 for instructions about installing the card.

9 Connect the SAS data cable to the SAS controller card, and to the SAS interface connector on the

backplane. See Figure 3-13 and Figure 3-12.

10 Close the system. See "Closing the System" on page 47.
11 Stand the system upright.

1

release tab

2

power connector

3

I2C connector

4

data cable

5

power cable

1

5

2

4

3

Advertising