Step 12: configure ports, Step 12, Dialog appears – Dell Compellent Series 30 User Manual

Page 30

Advertising
background image

24

Storage Center System Setup Guide

Setting Up the Storage Center

Figure 18. iSCSI IO Card Configuration Warnings

3 For each iSCSI IO card, correct the IP Address, Subnet Mask, and/or Gateway IP

Address.

4 When you have finished, click Save Configuration. Go to

Step 12: Configure Ports on

page 24

.

Step 12: Configure Ports

The first dialog that appears for this step depends on whether the Virtual Ports feature is
licensed on the Storage Center.

If...

Then...

Virtual Ports are Not Licensed

All transport types use Legacy Operational Mode. In this
case, the System Startup Wizard displays the Initial Port
Configuration dialog.

To continue, go to

Step 12a: Configure Ports – Virtual Ports

Not Licensed on page 26

.

Note

In Legacy Mode, Fault Domains associate Primary
and Reserved Front End ports to one another. The
Primary and Reserved ports designate the port to
which traffic is moved in the event of a failover or
revert. Each Fault Domain requires a Primary and
Reserved port. Reserved ports do not carry data
unless a Primary port fails, thus only half the ports
are used.