Dell Compellent Series 30 User Manual

Page 41

Advertising
background image

35

Configuring a System via the Startup Wizard

Figure 30. Initial Port Configuration Generated with no Warnings

5 Your next action depends upon the following:

If there are no warnings for either Fibre Channel or iSCSI and there is only one Fibre
Channel switch fabric, click Continue to proceed to

Step 13: Generate SSL

Certificate on page 43

.

If there are two Fibre Channel switch fabrics, you must select Configure Local
Ports
and create a new fault domain for the second switch. Follow your pre-
installation documentation for site-specific connections. Make sure that controller
ports physically connected to fabric 1 are in one fault domain and controller ports
connected to fabric 2 are in another fault domain. Proceed to

Configure Virtual Port

Mode Local Ports – FC on page 36

.

If there are warnings for either Fibre Channel or iSCSI, click Configure Local Ports
to modify the configuration and correct any issues that cause warnings. Proceed to

Configure Virtual Port Mode Local Ports – FC on page 36

or

Configure Virtual Port

Mode Local Ports – iSCSI on page 40

.

Configuring Virtual Port Mode Local Ports - FC and iSCSI

You modify local port configuration settings for both Fibre Channel and iSCSI ports by using
the dropdown menus and buttons that appear on the Configure Ports dialog.

For Fibre Channel ports, refer to

Configure Virtual Port Mode Local Ports – FC on

page 36

.

For iSCSI ports, refer to

Configure Virtual Port Mode Local Ports – iSCSI on page 40

.

Advertising