Dell Compellent Series 30 User Manual

Page 38

Advertising
background image

32

Storage Center System Setup Guide

Setting Up the Storage Center

Step 12b: Configure Ports – Virtual Ports Licensed

If Virtual Ports are licensed, a dialog appears allowing you to select an operational mode.
This dialog displays the following information:

•

Transport types that support Virtual Ports (currently FC and iSCSI)

•

Transport types where at least one port of the type exists on the Storage Center

Figure 27. Select Operational Mode

Common Action – Continue

1 Select the operational mode for FC and iSCSI transports. Default is Legacy Mode.

2 Click Continue to begin port initialization in the selected operational mode(s).

The wizard verifies the configuration, converts selected transports to the selected mode,
displays progress windows, and sends a confirmation window (Figure 28 on page 33)
when operational modes for transport types have been configured and initialized. If
issues are found, no transports are converted and a window listing errors is displayed.

Alternate Action – Skip Port Initialization

If you do not know the operational mode to be used or it is not specified in your pre-
installation documentation, you can choose to skip port initialization at this time.

1 Click Skip Port Initialization to leave all transports in Legacy Mode. If you skip port

initialization:

•

All ports remain uninitialized and have a status of Unknown.

•

All transports remain in Legacy Mode.

2 Go to

Step 13: Generate SSL Certificate on page 43

.

Advertising