Setting Up the Storage Center

Step 12b: Configure Ports – Virtual Ports Licensed

If Virtual Ports are licensed, a dialog appears allowing you to select an operational mode.
This dialog displays the following information:

Transport types that support Virtual Ports (currently FC and iSCSI)

Transport types where at least one port of the type exists on the Storage Center

Figure 27. Select Operational Mode

Common Action – Continue

1 Select the operational mode for FC and iSCSI transports. Default is Legacy Mode.

2 Click Continue to begin port initialization in the selected operational mode(s).

The wizard verifies the configuration, converts selected transports to the selected mode,
displays progress windows, and sends a confirmation window (Figure 28 on page 33)
when operational modes for transport types have been configured and initialized. If
issues are found, no transports are converted and a window listing errors is displayed.

Alternate Action – Skip Port Initialization

If you do not know the operational mode to be used or it is not specified in your pre-
installation documentation, you can choose to skip port initialization at this time.

1 Click Skip Port Initialization to leave all transports in Legacy Mode. If you skip port

initialization:

All ports remain uninitialized and have a status of Unknown.

All transports remain in Legacy Mode.

2 Go to

Step 13: Generate SSL Certificate on page 43

.