Warning – Qmark TBX - Tool Box Heater User Manual
Page 3

WARNING
ELECTRIC SHOCK HAZARD. DISCONNECT HEATER FROM
POWER SUPPLY BEFORE SERVICING AND/OR INSPECT-
ING THE HEATER.
!
REPLACEMENT PARTS LIST
REF
NO
DESCRPITION
PART NO.
QTY
1
Thermostat
5813-2059-000
1
2
Element: 9.5KW
302006813
1
7.5KW
302006814
1
3
Motor
490059004
1
4
Fan Blade
490011001
1
5
Element Contactor
5018-0006-002
1
6
Limit
410169001
1
7
Fan Relay
5018-0003-002
1
8
Time Delay
410171003
1
9
Wheel
6406-0002-000
2
10
Grille - Inlet
312007806
1
11
Grille - Outlet
2501-10513-800
1
12
Latch
3505-2002-000
1
13
Tool Box Handle
2710-10586-000
1
14
Handle
2710-2012-800
1
15
Terminal Block
480100001
1
16
Knob
3301-2053-000
1
*
Cord and Plug
1016-10593-000
1
* Not shown
1
2
3
4
5
15
7
6
9
10
14
12
13
11
16
MAINTENANCE INSTRUCTIONS:
Heaters should be cleaned and inspected periodically to
assure efficient safe operation. If power cord or plug
becomes damaged, repair or replace immediately. Do not
continue to operate unit with damaged cord or plug.
Using compressed air or vacuum, remove dust, dirt and
debris from heater element, fan blade and around motor to
allow for proper airflow through unit. While unplugged from
outlet, periodically check tightness of all electrical connec-
tions and all assembly hardware. Fan motor has permanently
lubricated bearings and requires no additional lubrication.
Clean exterior surfaces with mild soap and
water as necessary. Do not use harsh
chemicals. Exterior surfaces are of a
hight quality powder coat and should
not require repainting. However, if
desired, the exterior may be
repainted using high quality
enamel. However, care
must be taken to avoid
getting paint on interior
surfaces including heating
element and motor. Surfaces
should be sanded and
primed to help the new
paint to adhere.
8
Figure 4