Warning – Qmark TBX - Tool Box Heater User Manual

Page 3

Advertising
background image

WARNING

ELECTRIC SHOCK HAZARD. DISCONNECT HEATER FROM
POWER SUPPLY BEFORE SERVICING AND/OR INSPECT-
ING THE HEATER.

!

REPLACEMENT PARTS LIST

REF
NO

DESCRPITION

PART NO.

QTY

1

Thermostat

5813-2059-000

1

2

Element: 9.5KW

302006813

1

7.5KW

302006814

1

3

Motor

490059004

1

4

Fan Blade

490011001

1

5

Element Contactor

5018-0006-002

1

6

Limit

410169001

1

7

Fan Relay

5018-0003-002

1

8

Time Delay

410171003

1

9

Wheel

6406-0002-000

2

10

Grille - Inlet

312007806

1

11

Grille - Outlet

2501-10513-800

1

12

Latch

3505-2002-000

1

13

Tool Box Handle

2710-10586-000

1

14

Handle

2710-2012-800

1

15

Terminal Block

480100001

1

16

Knob

3301-2053-000

1

*

Cord and Plug

1016-10593-000

1

* Not shown

1

2

3

4

5

15

7

6

9

10

14

12

13

11

16

MAINTENANCE INSTRUCTIONS:

Heaters should be cleaned and inspected periodically to
assure efficient safe operation. If power cord or plug
becomes damaged, repair or replace immediately. Do not
continue to operate unit with damaged cord or plug.

Using compressed air or vacuum, remove dust, dirt and
debris from heater element, fan blade and around motor to
allow for proper airflow through unit. While unplugged from
outlet, periodically check tightness of all electrical connec-
tions and all assembly hardware. Fan motor has permanently
lubricated bearings and requires no additional lubrication.

Clean exterior surfaces with mild soap and
water as necessary. Do not use harsh
chemicals. Exterior surfaces are of a
hight quality powder coat and should
not require repainting. However, if
desired, the exterior may be
repainted using high quality
enamel. However, care
must be taken to avoid
getting paint on interior
surfaces including heating
element and motor. Surfaces
should be sanded and
primed to help the new
paint to adhere.

8

Figure 4

Advertising