Fig. 5 fig. 6 wiring installation – Qmark ASRV14 - Attic Ventilators User Manual

Page 5

Advertising
background image

TO MOTOR

WHITE

WHITE

BLACK

GROUND

THERMOSTAT

TO MOTOR

WHITE

WHITE

BLACK

GROUND

THERMOSTAT

DEHUMIDISTAT

JUNCTION

BOX

FIG. 5

FIG. 6

WIRING INSTALLATION

WARNING:

To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed
control device.

(This fan is designed to run on 120 volts, 60 Hz power only)

1.

Wiring of this unit is done inside of the attic. Remove cover from thermostat/junction box. Bring the
power cable at least 6” into the box. Fasten power cable to box with appropriate connector.

120 VOLT

SUPPLY

120 VOLT

SUPPLY

2.

For standard installation, connect the two leads in the thermostat/junction box to the two supply leads.
Attach ground wire from the supply to the green ground screw in the box. See Fig. 5.

3.

See Figure 6 for wiring dehumidstat to ventilator.

4.

Replace cover to thermostat/junction box.

5.

The ventilator will automatically turn “ON” when the attic temperature rises above 105 ºF and will turn
“OFF” when the temperature drops below 95ºF.

5