WARNING:

The motor is thermally protected and automatically temperature controlled and may start
without warning; therefore, make certain that the power source is disconnected before
attempting to service or disassemble any components! If the power disconnect is out of
sight, lock it in the open position and tag to prevent application of power.

TROUBLE SHOOTING CHART

WARNING: Items marked with an asterisk (*), should be performed only by experienced and qualified

personnel.

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

Excessive noise

1.

Propeller blade contacting housing

*

1. Realign or replace

2.

Foreign material inside housing

*

2. Clean

3.

Motor loose

*

3. Secure properly

4.

Motor needs oiling

*

4. See lubrication

5.

Dirt accumulation on propeller,

*

5. Clean

causing imbalance

Insufficient air flow

1.

Not enough eave vents to provide

*

1. See Installation

“make-up” air

2.

Clogged screen .

*

2. Clean or replace

Unit fails to operate

1.

Blown fuse or open circuit breaker

*1. Replace fuse or reset circuit

breaker

2.

Motor

*2. Replace

3.

Thermostat

*3. Replace

6

LUBRICATION: To prolong the life of the motor, oil motor every six months of use with S.A.E. 20

Motor Oil.