WALL MOUNT

CEILING MOUNT

I-BEAM MOUNT

1. Securely attach wall mount to either a wood or concrete wall.

(See fig. 7)

For installation on wood construction (minimum of 2” x 4”

stud), secure bracket with heavy duty lag bolts or screws (not

included). For concrete or masonry installation use heavy duty

expansion shields and lag screws (not included).

NOTE: All installations should be done to meet local building code.

2. Attach swivel mounting plate to end of bracket using 1/2” bolt, lock

washers, and hex nut. (See fig. 7)

3. Secure motor to wall mount using 1/2” x 1” hex bolt and 1/4”

x 1” bolt, washers, lock washers, and hex nuts. (See fig. 8)

4. Refer to nameplate for proper supply voltage. Plug power cord

from fan into any 120 VAC 3-prong grounded outlet for all 120

volt rated units. Units rated 220V or 277V are not supplied with

attachment plugs. These units may be hard wired to a junction

box or provided with the required 15 amp, 3 prong grounded plug

rated at 250V or 277V as per nameplate rating of the fan unit.

1. Securely attach ceiling mounting plate to either a wood or

concrete ceiling. (See fig. 9)

For installation on wood construction (minimum of 2” x 4”

stud), secure bracket with heavy duty lag bolts or screws (not

included). For concrete or masonry installation use heavy duty

expansion shields and lag screws (not included).

NOTE: All installations should be done to meet local building code.

2. Screw section of 1 1/2” pipe (Installer furnished, and threaded

on both ends) into mounting plate. Then screw fan head

mounting section onto pipe. (See fig. 10)

3.

Secure motor to ceiling mount using 1/2” x 1“ hex bolt and

1/4” x 1” bolt, washers, lock washers & hex nuts. (See fig. 11)

4. Refer to nameplate for proper supply voltage. Plug power cord

from fan into any 120 VAC 3-prong grounded outlet for all 120

volt rated units. Units rated 220V or 277V are not supplied with

attachment plugs. These units may be hard wired to a junction

box or provided with the required 15 amp, 3 prong grounded

plug rated at 250V or 277V as per nameplate rating of the fan unit.

1. Place two U-bolt I-beam clamps on threaded pipe - Position

threaded pipe on either horizontal or vertical I-beam and slide

U-bolt firmly on I-beam and tighten securely to beam.

(See fig. 12)

NOTE:All installations should be done to meet local building codes.

2. Screw mounting section securely onto threaded end of pipe

(See fig. 12)

3. Secure motor to I-beam mount using 1/2” x 1” hex bolt,

washers, lock washers, and hex nuts; and 1/4” x 1” bolt, washer,

lock washers and hex nut. (See fig. 13)

4. Refer to nameplate for proper supply voltage. Plug power cord

from fan into any 120 VAC 3-prong grounded outlet for all 120

volt rated units. Units rated 220V or 277V are not supplied with

attachment plugs. These units may be hard wired to a junction

box or provided with the required 15 amp, 3 prong grounded plug

rated at 250V or 277V as per nameplate rating of the fan unit.

Figure 7

Figure 8

Figure 9

Figure 11

Figure 10

Figure 13

(Not Included)