REMOVAL OF FRONT GUARD FOR

CLEANING OR MAINTENANCE

SECONDARY SUPPORT CABLE INSTALLATION

FOR WALL/CEILING AND I-BEAM MOUNTS

1. Turn off fan and unplug from power source!

2. Insert two screwdrivers as illustrated. (See fig. 14)

3. Carefully apply pressure on edge of rear guard

inward and pressure to front edge of guard outward

to disengage hook.

4. Work around guard until all hooks are disengaged.

5. To re-attach front of guard repeat step 3 of Fan Guard

Assembly instructions.

NOTE: Be careful not to bend edge of guards.

Figure 14

Figure 15

1. Always unplug power cord when servicing fan.

2. To reduce the risk of fire or electric shock do not use this

fan with any solid state motor speed control.

3. Never allow fan to become wet or damp.

4. Never move or adjust fan height while fan is running.

5. Never put fingers or foreign objects through fan guard.

6. Motor is permanently lubricated - do not oil.

7. Check all hardware periodically to make sure all is

secure. Loose hardware could cause damage to fan.

8. A secondary support cable should be used with any

overhead installation.

9. Extension cords should not be used with fans. If it is

necessary to use one, use only three wire extension

cords with three prong grounded type plugs. Refer to

table for correct wire size.

EXTENSION CORD LENGTH

WIRE SIZE AWG

UP TO 25 FEET

14

25-50 FEET

12

GENERAL SAFETY INFORMATION

Part No. 5200-2391-003

02/07

ECR 37011

4

Figure 16

Loop secondary support cable around top of fan guard as

indicated. Secure cable making sure both front and back guards are

inside loop, but that cable is not allowed to touch fan blade (See fig.

15). Secure ends with two cable clamps, loop other end of cable

around any permanent sturdy structural member close to fan (I-

beam, rafter, joist, etc...) and secure ends with two cable clamps.

IMPORTANT NOTICE: It is important to note the proper installation

position of the cable clamps as illustrated. To obtain maximum hold-

ing power, install U-bolt section of clip on dead or short end of cable

and saddle on long end of cable(See fig. 16). Improper installation

reduces the efficiency of the connection by as much as 40 percent.

HOW TO OBTAIN WARRANTY SERVICE AND

WARRANTY PARTS PLUS GENERAL INFORMATION

1. Warranty Service or Parts

1-800-642-4328

2. Purchase Replacement Parts

1-800-654-3545

3. General Product Information

www.marleymep.com

Note: When obtaining service always have the following:

1. Model number of the product

2. Date of manufacture

3. Part number or description

470 Beauty Spot Rd. East

Bennettsville, SC 29512 USA

Advertising
This manual is related to the following products: