Memories

BRAM80KFIFO

Speedster22i Macro Cell Library

Achronix Semiconductor Proprietary

PAGE 130

rdrst_sync_stages

The  rdrst_sync_stages  parameter  defines  the  number  of  stages  of  registers  used  to 
synchronize  the  rdrst  input  pin  to  the  wrclk  clock  domain  if  the  rdrst  signal  is  used  by  the 
Write  Pointer  Reset.  The  value  of  the  rdrst_sync_stages  parameter  is  only  used  if  the 
wrrst_input_mode is set to 2’b10 or 2’b11.  The mapping of the rdrst_sync_stages parameter 
value  to  the  number  of  sychronization  stages  is  defined  in 

Table  6‐31:  Mapping 

rdrst_sync_stages  Parameter  Settings  to  Synchronization  Stage  Depth

,  where  each  stage 

corresponds  to  a  register  in  the  Read  Reset  Synchronizer  shown  in 

Figure  6‐9:  Read  and 

Write Pointer Reset Input Selection Block Diagram

. For example, setting rdrst_sync_stages 

to 2’b00 configures the rdrst synchronization circuit to have two back‐to‐back registers in the 
Write Reset Synchronizer.  The default value of the rdrst_sync_stages parameter is 2’b00.

Table 6-31: Mapping rdrst_sync_stages Parameter Settings to Synchronization Stage Depth

rdrst_sync_stages

Read Reset Synchronization Stage Depth

2’b00

2

2’b01

3

2’b10

4

2’b11

5

rdptr_sync_stages

The  rdptr_sync_stages  parameter  defines  the  number  of  stages  used  in  the  Read  Pointer 
Synchonizer circuit that synchronizes the Read Pointer to the wrclk clock domain.  When the 
FIFO  is  in  asynchronous  mode,  (sync_mode  =  1’b0),  the  output  of  the  synchonized  Read 
Pointer  is  compared  to  the  Write  Pointer  to  generate  the  full  and  almost_full  flags.    The 
synchronized Read Pointer may also be routed to the rdcounter output (rdcount_sync_mode = 
1’b0). The mapping of the rdptr_sync_stages parameter value to the number of sychronization 
stages is defined in 

Table 6‐32:  Mapping rdptr_sync_stages Parameter Settings to Synchro‐

nization  Stage  Depth

,  where  each  stage  corresponds  to  a  register  in  the  Read  Pointer 

Synchronizer  circuit  shown  in 

Figure  6‐11:  Read  Pointer  Synchronizer  Block  Diagram

. 

Higher  values  for    the  rdptr_sync_stages  parameter  reduce  the  possibility  of  a  metastable 
event  when  transferring  the  Read  Pointer  across  clock  domains.  As  an  example,  setting 
rdptr_sync_stages  to  2’b00  configures  the  read  pointer  synchronization  circuit  to  have  two 
back‐to‐back  registers  in  the  Read  Pointer  Synchonizer.    The  default  value  of  the 
rdptr_sync_stages parameter is 2’b00.

Table 6-32: Mapping rdptr_sync_stages Parameter Settings to Synchronization Stage Depth

rdptr_sync_stages

Read Pointer Synchronization Stage Depth

2’b00

2

2’b01

3

2’b10

4

2’b11

5

wrcount_sync_mode

The  wrcount_sync_mode  parameter  defines  whether  the  write  counter  (wrcount)  output  is 
synchonous  to  the  wrclk  clock  input.  Assigning  a  value  of  1’b0  to  wrcount_sync_mode 
configures the wrcount output to be synchonized to the rdclk clock. Assigning a value of 1’b1 
to wrcount_sync_mode configures the wrcount output to be synchonized to the wrclk clock. 
The default value of the wrcount_sync_mode parameter is 1’b1.