Delayed egress operations, Green led red led pushpad (lhr shown), Mortise cylinder position home key siren – Detex Delayed Egress With Magnetic Lock User Manual

Page 13

Advertising
background image

A 9-volt battery is included as a backup power source for the alarm siren if power is lost.

To disable low battery indication, slide "DisLoBat" switch to 'ON'. See EM ELECTRICAL OPTIONS page.

LOW BATTERY INDICATION

If battery voltage is low (7 volts or less), unit remains armed but LED flashes RED and unit beeps

twice every 45 seconds. Replace battery as soon as possible.

BATTERY BACKUP FOR ALARM

With door closed, insert key in the cylinder, turn CCW then back to the home key position and remove it.

LED glows green. Authorized personnel can exit the door during this rearm cycle. After a 1, 5 or 15-second

arming period, alarm issues three quick beeps and LED goes off, indicating that the unit is armed.

Insert key, turn CW to a stop. Green LED will blink twice to indicate the unit is disarmed.

To exit, push and maintain pressure on the pushpad. LED flashes RED and alarm pulses on and off for 15

seconds. After 15 seconds, alarm issues short and long pulses to indicate that you can exit by depressing

the pushpad. Alarm sounds continuously and LED is steady RED. Turn key CW to stop alarm. In case of fire,

the fire alarm over-rides the 15 second delay and the door opens without delay when the pushpad is pushed.

ARMING AND AUTHORIZED EXIT

performing alarm test operations

push and hold deadlatch while

NORMAL OPERATION

EXITING UNDER ALARM

DISARMING

For BENCH TESTING:

Deadlatch

Turn Key CW To Disarm

Red LED while alarming

Glowing Green LED

Turn Key CCW To Arm

Green LED

Red LED

PushPad

(LHR shown)

DELAYED EGRESS OPERATIONS

Mortise

Cylinder

Position

Home Key

Siren

Indicates the unit is in process of arming. The siren will chirp three times to indicate the unit

is armed and green LED will turn off

DOUBLE BLINK

DOUBLE CHIRP

OFF

LED COLOR

SLOW BLINKING

FAST BLINKING

ON

ON

OFF

RED
OFF

Pushpad is depressed, delay to open started

This indicates either armed or disarmed

Delay to open expired, door has been opened

ON

SLOW PULSE

FAST PULSE

OFF

OFF

OFF

ON

OFF

SIREN SOUNDS

THREE CHIRPS

GREEN

ON

FUNCTION

BLINK

BLINK

OFF

OFF

Factory installed jumper removed from terminals 3 & 4

Delay to open expired

Low Battery - every 45 seconds
Armed - status ON

Disarmed - ON

103182 Page 13