C - SILL FLASHING INSTALLATION

INSTALL THE SILL FLASHING CONTINUOUSLY BETWEEN

SECTION IV ASSEMBLY & INSTALLATION

ALL THERMAL STRUT SILL FLASHING THAT COULD
ENCOUNTER MOISTURE MIGRATION MUST HAVE THE

across the top of the thermal strut

Apply a continuous bead of sealant

THERMAL STRUT SEALED OVER WITH SILICONE.

sealant (i.e., silicone).

"skinning", nonhardening type of

Seal the ends of the flashing with a

THE MASONRY JAMBS OR BETWEEN THE DOOR FRAME
AND THE MASONRY JAMB. SEE FIGURES BELOW.

to ensure that the hole through the sill
flashing is sealed.

inserted, force sealant into the hole

Anchor the sill flashing 6" from verticals
and 24" O.C. Before the fastener is

Seal over the heads of all
flashing attachment screws.

FIG. #26

Sealant

Sealant

NOTE:

when using thermal flashing.

8731

STEP 1)

1G86 SIMILAR.

1G83 SHOWN,

FIG. #27

bead of sealant.

set it in a continuous

until it is level and

Shim the flashing

Sill flashing options:

Sealant

1G86 - w/ STOOLS

1G83 - STANDARD

9738

THERMAL

{

BAH 4/2005

PAGE 25