Kontron AM4204 User Manual

Page 18

Advertising
background image

3

AM4204

www.kontron.com

Dual Gigabit Ethernet

Controller

•

Dual Gigabit Ethernet Controller Intel 82571EB

•

PCIe x4 interface to processor

•

2 1000Base-BX (Serdes) interfaces to AMC connector

•

Serial-over-LAN Support via SMB

IPMI

•

IPMI 1.5 compliant

•

Voltage and Temperature Sensors

•

ATCA LED control

•

FRU data storage for AMC

•

Firmware Update handling for field upgrades, rollbacks and watchdog functions

I/O Interfaces

•

Front: 4 SFP cages to support multi-rate copper and fiber SFP modules

•

AMC TCLKA support

•

AMC FCLKA input with 100MHZ without SSC

•

AMC Port 0 and Port 1: 1000Base-BX

•

AMC Port 4 to Port 7: Configurable x4 PCIe Root Complex or target mode

•

AMC port 8 to port 11 : 1000Base-BX or 10G-Base-BX4 (XAUI)

•

AMC Port 15: RS232 (proprietary mapping)

Standards Compliance

•

This board is compatible to the following standards:

•

AMC.0 R2.0 Advance Mezzanine Card Base Specification

•

AMC.1 R2.0 PCI Express and Advance Switching

•

AMC.1 Type 4

•

AMC.2 R1.0 AMC Gigabit Ethernet

•

AMC.2 Type 4 E2

•

AMC.2 Type 5 E2

•

IPMI v1.5.

•

IEEE 802.3

•

The AM4204 is RoHS compliant.

Mechanical

Characteristics

•

4HP single Mid-size AMC Module

•

Board is compliant with AMC.0 R2.0

Operating Voltages

•

Management:

3.3V +/-0.3V

•

Payload:

10VDC to 14VDC

Operation Power

•

Management:

500mW max., 400mW typ.

•

Payload:

36W max., 29W typ.

Temperature

•

This board is designed for operation from 5°C to 70°C ambient air temperature with forced

convection.

•

Operating @ 10 CFM:

5°C to 45°C

•

Operating @ 15 CFM:

5°C to 65°C

•

Short term operating @ 25 CFM:

-5°C to 75°C

•

Non-Operating:

-40°C to 70°C

Humidity

•

The board is designed to meet Bellcore GR63, Section 4.1

•

Operating:

15%-90% (non-condensing) at 55°C

•

Non-Operating:

5%-95% (non-condensing) at 40°C

Altitude

•

The board is designed to meet the following requirements according to Belcore GR-63, section

4.1.3:

•

Operating:

4000 m (13123 ft) (GR63 4.1.3), may require

additional cooling above 1800m (5905ft)

•

Non-Operating:

15000 m (49212 ft)

Features

Description

Advertising