4 kontron reset, 5 kontron post code value, 6 kontron diagnostic status – Kontron AM4204 User Manual

Page 54: Figure 5-1: kontron diagnostic status sensor

Advertising
background image

39

AM4204

www.kontron.com

5.1.2.1.4

Kontron Reset

5.1.2.1.5

Kontron POST Code Value

5.1.2.1.6

Kontron Diagnostic Status

Table 5-5:Kontron reset sensor

Event/Reading type
code

Sensor type

Sensor specific offset Event trigger

03h

CFh
OEM Kontron

RESET

00h
01h
State Asserted /

State Deasserted

Event Data 2: Reset Type
00h: Warm reset
01h: Cold reset
02h: Forced Cold [Warm reset reverted to Cold]
03h: Soft reset [Software jump]

Event Data 3: Reset Source
00h: IPMI Watchdog [cold, warm or forced cold]
(IPMI Watchdog2 sensors gives dditional details)
01h: IPMI commands cold, warm or forced cold]
(chassis control, fru control)
02h: Processor internal checkstop
03h: Processor internal reset request
04h: Reset button [warm or forced cold]
05h: Power up [cold]
06h: Legacy Initial Watchdog / Warm Reset Loop Detection

* [cold reset]
07h: Legacy Programmable Watchdog [cold, warm or forced

cold]
08h: Software Initiated [soft, cold, warm of forced cold]
09h: Setup Reset [Software Initiated Cold]
FFh: Unknown

Table 5-6:Kontron POST code value sensor

Event/Reading type
code

Sensor type

Sensor specific offset Event trigger

6Fh

C6h
OEM Kontron POST

Code Value

14h

POST Code Error Event Trigger
Event Data 2: POST Low
Event Data 3: POST High (always 00h)

Figure 5-1:Kontron diagnostic status sensor

Event/Reading type
code

Sensor type

Sensor specific offset Event trigger

6Fh

C9h
OEM Kontron
Diagnostic Status

00h

Diagnostic Started

01h

Diagnostic PASS

02h

Diagnostic FAIL

Advertising