4. Thermal Considerations

4.1

Thermal Monitoring

To ensure optimal operation and long-term reliability of the AM4204, all onboard components must remain
within the maximum temperature specifications. The most critical components on the AM4204 are the
processor and the Dual GE Phy. Operating the AM4204 above the maximum operating limits will result in
permanent damage to the board. To ensure functionality at the maximum temperature, the Module
Management Controller supports several temperature monitoring and control features.

The AM4204 includes three temperature sensors that are accessible via the Module Management Controller.
Although temperature sensing information is made available to the MMC, the AM4204 itself does not provide
any active means of temperature regulation.

Figure 4-1:Temperature Sensor Locations (AM4204 Top View, heat sinks not shown)

The Temp CPU and the Temp Dual GE sensors are on-chip sensors which measure the die temperature of the
Octeon Processor and the Dual GE PHY. The Temp Air Out sensor is a separate sensor measuring the
temperature in the slipstream of the processor. This is the spot with the highest outlet air temperature. .

The following table shows the temperature thresholds of all three sensors.