7 kontron user sw upgradestatus, 2 sensor thresholds, 3 health error – Kontron AM4204 User Manual

Page 55

Advertising
background image

40

AM4204

www.kontron.com

5.1.2.1.7

Kontron User SW upgradeStatus

5.1.2.2

Sensor Thresholds

Following table shows sensor thresholds for voltages

Table 5-8:Voltage sensor thresholds

5.1.2.3

Health Error

The Health Error is asserted if one of the sensors mentioned in Table 5-8 on page 40 (Voltage sensor
thresholds) exceeds UC, UNR, LC or LNR or one of the sensors mentioned in Table 4-1 (Temperature Sensor
Thresholds) in Chapter 4.1 exceeds UC or UNR.

Table 5-7:Kontron user SW upgrade status sensor

Event/Reading type
code

Sensor type

Sensor specific offset Event trigger

6Fh

CAh
OEM Kontron

External

Component

Firmware Upgrade

Status

00h

Firmware Upgrade in Progress (no event)

01h

Firmware upgrade succeeded

02h

Firmware upgrade failed

SENSOR Number / ID string

Lower Non-Re-
coverable

Lower criti-
cal

Lower non
critical

Upper non
critical

Upper crit-
ical

Upper Non-Re-
coverable

ID=15: Vcc 1.0V

na

1.01 V

1.03 V

1.18 V

1.294 V

na

ID=16: Vcc 1.0V BCM (AM4220

and AM4210 only)

na

0.88 V

0.93 V

1.08 V

1.465 V

na

ID=17: Vcc 1.1V

na

1.01 V

1.02 V

1.18 V

1.67 V

na

ID=18: Vcc 1.2V

na

1.10 V

1.13 V

1.28 V

1.29 V

na

ID=19: Vcc 1.8V

na

1.65 V

1.68 V

1.92 V

2.06 V

na

ID=20: Vcc 3.3v

na

3.05 V

3.06 V

3.55 V

3.56 V

na

ID=21: Vcc 3.3V SUS

na

2.92 V

2.93 V

3.69 V

3.70 V

na

ID=23: Vcc 12v

na

8.36 V

9.7 V

14.45 V

15.52 V

na

Advertising