3 oem set serial configuration, 4 oem set control state – Kontron AM4204 User Manual

Page 57

Advertising
background image

42

AM4204

www.kontron.com

5.1.3.3

OEM Set Serial Configuration

Example: Using onboard

ipmitool –l 3 raw 0x30 0x06 0xab 0xca 0xca 0xce 0xc9 <setting>

5.1.3.4

OEM Set Control State

• The MMC shall support the following Control Ids

• The MMC shall save and restore these settings.

• The MMC shall immediately restart the payload of the module on change of the “interface settings”.

Command Name

LUN

NetFn

Command Number

OemApSetSerialconfig

3

0x30

0x06

Byte Num

Data Field / Byte Raw

Request Data

1...5

0xAB 0xCA 0xCA 0xCE 0xC9

6

MUX setting

Response Data

1

Completion Code

Command Name

LUN

NetFn

Command Number

CmdSetControlState

0

0x3E

0x20h