4

AM4204

www.kontron.com

1.4

Hot Swap Capability

The AMC supports Full Hot Swap capability as required by AMC.0 R2.0. It can be removed from or installed in
the system while it is on (without powering-down the system). Please refer to the AMC.0 R2.0 specification
for additional details.

Vibration

The board is designed to meet the following requirements according to EN 300 019, Telcore GR-

63 and IEC 60068:

Operating:

• 5 Hz to 200Hz 0.2G, 5mm/s (sinusoidal)
• 5 Hz to 100Hz: 0.1G @ 0.1 Octave/minute (sinusoidal)
• 5 Hz to 100Hz: 1G @0.1 Octave/minute (sinusoidal)
• 0,02 m²/s³ ASD, 5-10Hz +12dB/oct, 10-50Hz 0dB/oct, 50-100Hz -12dB/oct (random)

Non-Operating (packaged enclosure):

• 5 Hz to 200Hz 2G, 5mm/s (sinusoidal)
• 0,02 m²/s³ ASD, 5-10Hz +12dB/oct, 10-50Hz 0dB/oct, 50-100Hz -12dB/oct (random)
• 5 Hz to 20 Hz: 0.01g²/Hz (random)
• 20 Hz to 200 Hz: -3dB/octave (random)

Shock

The board is designed to meet the following requirements according to EN 300 019, Telcore GR-

63 and IEC 60068:

Operating:

3G, 11ms Shock

Non-Operating

18G, 6ms Shock

1000mm/all edges and corners Free Fall (packaged)

100mm/all edges and corners Free Fall (unpackaged)

Safety

CB report to IEC 60950-1, complies with EN/CSA/ UL 60950-1.

The board is designed to meet the following flammability requirement (as specified in Telcordia

GR-63-CORE):

UL 94V-0/1 with Oxygen index of 28% or greater material

Electromagnetic

Compatibility

The board is designed to meet or exceed of the following specifications/requirements (assuming

an adequate carrier/chassis):

FCC 47 CFR Part 15, (USA)

EMC Directive 89/336/EEC (Europe)

EN55022 (Europe)

EN55024 (Europe)

CISPR22

VCCI (Voluntary Japan Electromagnetic Compatibility requirement)

EN 300 386, Electro-Magnetic Compatibility (EMC) Requirements for Public Telecommunication

Network Equipment; Electromagnetic Compatibility (EMC) Requirements

Telcordia GR-1098

ETSI/NEBS requirements

This board is designed to meet NEBS Level 3, Earthquake Zone 4