Hp-175-225 10, Integral diverter horizontal glazing details – Oldcastle BuildingEnvelope HP-175 User Manual

Page 10

Advertising
background image

NHP-5A GASKETS.

CUT HORIZONTAL

GASKETS D.L.O.

+ 1/4" PER FOOT.

MARK LOCATION OF EACH

GLAZING CLIP PRIOR TO

INSTALLING FACE CAPS.

HP-36 TEMPORARY

CLIPS. SLIDE ONTO

GLAZING CLIPS.

SETTING BLOCK MAY BE

MODIFIED TO FIT VARIOUS

GLASS THICKNESSES. TEAR

BLOCK FOR DESIRED SIZE.

5/8"

1/4"

1"

SEAL INTERIOR CORNERS OF

GASKETS AS SHOWN. FORCE

SEALANT INTO JOINT BETWEEN

GASKETS.

GLAZING NOTE:

GLAZE SYSTEM FROM BOTTOM

TO TOP. INSTALLING DIVERTERS

TO HORIZONTAL ABOVE AS YOU

PROCEED UP BUILDING.

HP-17

SETTING

BLOCK

GLASS SIZING

HP-175 = D.L.O. + 3/4"

HP-225 = D.L.O. + 1"

NHP-5A GASKETS

VERTICAL GASKETS TO

RUN THROUGH AND ADD

1/4" PER FOOT

CAUTION:

BE CERTAIN THAT GLASS IS PLACED

FIRMLY AGAINST INTERIOR GASKET

BEFORE SETTING ON BLOCKS. GLASS

BREAKAGE CAN OCCUR AT OR NEAR

SETTING BLOCKS DUE TO THE WEIGHT

NOT ALLOWING THE GLASS TO MOVE

TOWARD INTERIOR GASKET.

LUBRICATING THE TOP OF THE

SETTING BLOCK WILL HELP INSURE

PROPER SETTING OF GLASS

INTEGRAL DIVERTER HORIZONTAL

GLAZING DETAILS

H P - 1 7 5 / 2 2 5 I N S T A L L A T I O N M A N U A L

10




