HP-10463

ATTACH W/ FS-6

(#10 X 3/4 PPH)

@ 12" O.C.

BED IN SEALANT

WATER DIVERTER

HP-10443

"A"

"A"

SECT "A-A"

ATTACH ANGLE TO

CORNER CLOSURE

AT HEAD & SILL

FORMED ALUM. CORNER

COVER. ATTACH W/

FS -7 (#10 X 3/4" PFH)

@ TOP & BOTTOMOF

COVER (MIN.)

NOTE:

REFERNCE STANDARD MULL

DRAWINGS FOR ADDITIONAL

INFORMATION.

HP-10462

AN-1 ANGLE

ATTACH W/ FS-6 @ 18" O.C.

DIVERTER BRIDGE

MODIFY AS SHOWN.

SEA LANT NOT SHOWN

FOR CLARITY. *

NOTE:

USE TYPICAL MULL CAPS AND

MODIFY SIMILAR TO JAMB CAPS.

(SEE SHEET #6)

THEN MARRY SEAL ACROSS MULL

CAPS AND ANGLES ATTACHED TO

CORNER CLOSURE.

* USE STANDARD DIVERTER BRIDGE

AT HORIZONTALS AND MODIFY AS

SHOWN IN DETAIL ABOVE. SEAL PER

STANDARD BRIDGE DETAILS ON SHEET 9.

HP175-FP-65

END CAP