Hp-175-225 07, Sealant procedures for jambs & mulls – Oldcastle BuildingEnvelope HP-175 User Manual

Page 7

Advertising
background image

1"

MIN.

1/2"

FS-43

(#12 X 3/4" PPH)

SEAL FACE & SIDES

OF SHEAR BLOCK

MAXIMUM END REACTION

625 Lbs.

SEAL FACE, SIDE &

MARRY WITH

MULL CAP SEAL

CAP SEAL ALL

FASTENERS IN

GLAZING POCKET

HP175-FP-59 MULL CAP

MODIFIED, LOCATE AT

EACH END OF HEAD & SILL

FS-202

(#8 x 1/2" PPH)

BED MULL CAP

IN SEALANT

DRILL .149 (#25 BIT)

CLEAR HOLE

11/16"

11/16"

CUT D.L.O.

SEALANT PROCEDURES

FOR JAMBS & MULLS

H P - 1 7 5 / 2 2 5 I N S T A L L A T I O N M A N U A L