Hp-175-225 21, Butt glaze mulli0n glazing details – Oldcastle BuildingEnvelope HP-175 User Manual

Page 21

Advertising
background image

GLASS JOINT

(NO SPLICE IN CAP)

NOTE: LEAVE SPACE IN

GASKET AT BOTTOM FOR

WEEPAGE

WITH SEALANT,MARRY WEATHER

SEAL TO GASKET AT TOP

GLASS JOINT

(SPLICE IN CAP)

MARRY WEATHER SEAL

@ GLASS TO WEATHER

SEAL @ FACE CAP

NOTE: LEAVE SPACE IN

GASKET & SEALANT AT

BOTTOM FOR WEEPAGE

WEATHER SEAL

OPEN CELL

BACKER ROD

WHEN INSTALLING FACE CAPS

USE DEADBLOW HAMMER AND

IMPACT CAPS AT LOCATIONS

OF GLAZING CLIPS ONLY.

GASKET NOTE:

PRE-CUT NHP-5A GASKETS F OR FACE

CAPS, ALLOWING 1/4" PER FOOT

ADDITIONAL LENGTH FOR SHRINKAGE.

SEE DETAI L BELOW FOR INSTRUCTIONS

ON GASKET CUT LENGTH AT UNDERSIDE

OF HORIZONTAL.

GLASS SIZING

HEIGHT = D.L.O. + 3/4"

WIDTH = D.L.O. + 1 1/4"

BUTT GLAZE MULLI0N

GLAZING DETAILS

H P - 1 7 5 / 2 2 5 I N S T A L L A T I O N M A N U A L