Hp-175-225 24, Outside 90° mullion assembly – Oldcastle BuildingEnvelope HP-175 User Manual

Page 24

Advertising
background image

1"MIN.

1 1/4"

1 7/32"

HP175-FP-57 MULL CAP

@ SILL & HEAD

ATTACH W/ FS-23

(#6 X 3/8" PPH)

BED IN SEALANT

FS -43 (#12 X 3/4" PPH)

SET HORIZONTAL IN

SEA LANT AT MULL CAP

SEA L FACE, TOP

& BOTTOMOF

SHEAR B LOCK

CUT SILL & HEAD

DLO- 1/16"

CUT HORIZ. DLO

INTERIOR MULL

COVER

45˚

FAB NOTE:

SQUARE CUT HORIZONTAL

TO FACE OF GASKET RACE

ANDMITER AT 45˚.

HP-10459

ATTACH W/ FS-55

@ 18" O.C.

OUTSIDE 90° MULLION

ASSEMBLY

H P - 1 7 5 / 2 2 5 I N S T A L L A T I O N M A N U A L

24




