CUT NHP-5A GASKET 3/4" SHORT

ON BOTTOM SIDE OF HORIZONTAL

FACE CAPS AT BOTH ENDS.

WHEN INSTALLING FACE CAPS

USE DEADBLOW HAMMER AND

STRIKE CAPS AT LOCATIONS

OF GLAZING CLIPS ONLY.

INSTALL VERTICAL CAPS

FIRST, THEN HORIZONTALS.

3/4"

GLASS SIZING

HP-175 = D.L.O. + 3/4"

HP-225 = D.L.O. + 1"

GASKET NOTE:

PRE-CUT NHP-5A GASKETS FOR

FACE CAPS, ALLOWING 1/4" PER FOOT

ADDITIONAL LENGTH FOR

SHRINKAGE. SEE DETAIL BELOW FOR

INSTRUCTIONS ON GASKET CUT

LENGTH AT UNDERSIDE OF

HORIZONTALS.

CAP INSTALLATION NOTE:

TO INSTALL FACE CAPS, LOCATE

CAP ONTO CLIPS AT EACH END.

PRESS FIRMLY AGAINST CAP

UNTIL GASKET IS COMPRESSED

AGAINST GLASS AND STRIKE AT

PREVIOUSLY MARKED

LOCATIONS OF GLAZING CLIPS.

WHEN INSTALLED PROPERLY

CAPS SHOULD RESIST ROTATION.

INTEGRAL DIVERTER HORIZONTAL

GLAZING DETAILS

H P - 1 7 5 / 2 2 5 I N S T A L L A T I O N M A N U A L